Range Hood + Venting Service
Why this matters
Range hoods are the kitchen ventilation appliance - moving smoke + grease + heat outdoors during cooking. Code requirement in many jurisdictions (especially gas ranges + induction with above-cooktop venting). Average service. Many customers ignore the hood until it fails OR the kitchen smell tells them it's not working. Tech who can service AND quote replacements builds a steady revenue stream + protects customers from grease-fire risk.
Hood types
Under-cabinet range hood
- Most common residential
- Mounts under wall cabinets above range
- Width: 24", 30", 36" common
- CFM: 200 - 500 typical
- Recirculation (charcoal filter, NO outside vent) OR ducted (vent to exterior)
Wall-mount chimney hood
- Decorative chimney style; visible duct cover
- 30" - 48" widths
- CFM: 400 - 1,200
- Ducted (almost always); recirculation rare in chimney style
Island hood
- Mounts above island cooktop; ceiling-suspended
- 30" - 48" widths
- CFM: 500 - 1,500 (needs more for unobstructed cooking)
- Always ducted; long vent run common
Downdraft / pop-up vent
- Cooktop-side ventilation; rises during use
- Lower CFM but eliminates overhead hood
- Common in island layouts where overhead obstruction is undesired
Microwave with vent (OTR hood/microwave combo)
- Most common in builder-grade kitchens
- CFM: 150 - 400 (insufficient for serious cooking)
- Often the customer's first complaint: "my hood doesn't pull smoke" - usually correct; OTR hoods are weak
Pro / commercial-style hood
- Wall-mount or chimney
- CFM: 800 - 1,500+
- Stainless construction; commercial-grade fans
- Used with professional cooktops + ranges
CFM sizing
- Recommended: 100 CFM per linear foot of cooktop, OR 1 CFM per 100 BTU of gas burner output
- Standard 30" gas cooktop with 60,000 BTU total: 600 CFM minimum
- Pro range (45,000 - 80,000 BTU/burner × 6 burners = 270,000+ BTU): 1,000 - 1,500+ CFM
- High CFM (>400) requires makeup air per IRC (M1503.4) for sealed-house performance
Common failures
Failure 1: Fan won't run
- Switch / control fault
- Motor capacitor fault (AC motors)
- Motor seized
- Wiring damage (heat + grease attack on wires over years)
Diagnostic:
- Verify power at hood (most are hardwired; some plug-in)
- Test motor capacitor (test bench OR replace as diagnostic)
- Test switch continuity
- If motor + capacitor OK, switch + wiring is the fault
Failure 2: Fan runs but no airflow
- Filter clogged with grease (most common)
- Damper stuck closed (backdraft damper at hood exit)
- Duct obstructed (lint, bird's nest, ice in winter)
- Vent termination cap closed or bird-screen blocked
Diagnostic:
- Remove filter; clean or replace
- Inspect damper movement
- Visual inspection of duct from hood up to termination
- Check exterior termination cap
Failure 3: Excessive noise
- Worn motor bearings - replace motor or whole hood
- Loose impeller - tighten or replace
- Cabinet vibration - secure mounting
- Duct rattle - secure duct supports
Failure 4: Light doesn't work
- Bulb (most common; halogen + LED replacements available)
- Light switch
- Wiring
Failure 5: Backdraft / outside air entering through hood
- Damper failed open
- High wind + no damper
- Replace damper OR add second damper at exterior cap
Recirculation vs ducted (the big distinction)
Ducted: vents to exterior; removes grease + moisture + heat; preferred whenever possible.
Recirculation: filters grease through charcoal filter + returns air to kitchen. Removes 50 - 70% of grease (with new filter); does NOT remove moisture or heat or much smell. Customers complain because expectations don't match what recirculation can deliver.
Convert recirculation to ducted whenever possible:
- Determine vent run path: shortest possible to exterior
- 4 - 6" round duct standard for most residential hoods
- Rigid duct preferred; flex if curved path; smooth metal interior
- Minimum bends; maximum 25 - 35 ft equivalent length (varies by hood spec)
- Terminate at wall or roof cap with backdraft damper
- Insulate duct in unconditioned spaces
Filter maintenance (most-ignored item)
Grease filters (metal mesh)
- Clean every 1 - 3 months residential
- Dishwasher safe (most)
- Replace if damaged; metal mesh lasts 10+ years with care
Charcoal filters (recirculation only)
- Replace every 3 - 6 months
- DO NOT clean - saturated charcoal can't be regenerated
- Skipped maintenance = recirculation hood becomes a fan moving grease around
Replacement decision
- Hood 10+ years + multiple failures: replace
- Light fault + working fan: repair
- Motor + bearing failure: usually replace whole hood
- CFM inadequate for cooking style: upgrade to higher CFM
- Recirculation to ducted: upgrade opportunity (premium quote)
Code compliance
- Local building code may REQUIRE ducted ventilation for gas ranges
- Makeup air required if installed hood >400 CFM in tight house
- Termination distance from windows + intakes per IRC
- Backdraft damper required at termination
Some local AHJ require permit for new vent install - confirm with customer.
Replacement install (under-cabinet)
- Disconnect power; disconnect duct; remove screws from inside cabinet; lift old hood out
- Configure new hood: ducted vs recirc, duct adapter
- Lift into position; drive screws from inside cabinet bottom into hood top
- Slip duct over adapter; seal with foil tape (not fabric duct tape); secure with sheet-metal screws
- Hardwire OR plug-in; verify polarity + ground
- Power on; verify fan speeds + light + damper; customer walkthrough
The single biggest hood-performance customer complaint is "my hood doesn't pull smoke." 95% of the time, the cause is one of three: (1) hood CFM too low for the cooking style; (2) duct run too long with too many bends; (3) recirculation mode in use without owners realizing. Diagnose duct + CFM BEFORE quoting hood replacement - many installs are salvageable by upgrading to higher CFM hood + verifying duct is open + ducted-not-recirc. Save the customer a full rip-out + win the trust.
References
- IRC (International Residential Code) - M1503 hood requirements
- ASHRAE 62.2 (residential ventilation)
- Manufacturer install guides
- Manuall internal: Oven + Range Service, Appliance Diagnostic Error Codes - Troubleshooting