Chimney Sweep Service SOP
Purpose
Standardize the residential chimney sweep. The core revenue line of the trade + the visit where most upsells originate (cap install, riser, dryer-vent add, gas-log service).
Scope
Wood-burning fireplaces + wood stoves + open masonry chimneys. Pellet stove + gas appliance flues use the same containment but a different brush set. Excludes oil + coal flues (creosote chemistry differs, separate procedure).
Prerequisites
- CSIA certification preferred (matters for insurance + customer trust)
- Brush set sized to flue (round 6"-12", square 8x8-13x13, rectangular custom)
- Fiberglass rods (typically 30-50 ft total)
- HEPA vacuum (NOT a shop-vac - soot is sub-micron)
- Drop cloths + plastic sheeting + masking tape
- Flashlight + inspection camera
- Respirator (P100 minimum) + safety glasses + gloves + coveralls
- Roof harness + 24-32 ft extension ladder (top-down access)
- 1.5-2.5 hours per typical fireplace
Procedure
Step 1: Pre-arrival
Confirm last sweep date + fuel type (cordwood vs duralog vs both - duralog leaves glaze). Verify pets contained + furniture moved away from hearth.
Step 2: Containment
- Lay drop cloth from hearth 6 ft into room
- Tape plastic sheeting across fireplace opening (HEPA vacuum hose punches through)
- Open damper before sealing
- Verify HEPA suction at the sheet - negative pressure keeps soot inside the flue
- Move couch + rug clear
Step 3: Inspect first
Run inspection camera up the flue from the firebox. Document:
- Creosote stage (1 sooty, 2 flaky, 3 glazed)
- Liner condition (cracks, gaps, displacement)
- Smoke chamber finish (parging vs corbel)
- Damper function
- Any obstructions (nest, leaves, dead bird)
This determines brush vs chemical vs no-sweep-do-relining-instead.
Step 4: Sweep
Two methods. Choose by access + flue geometry:
Top-down: ladder to roof, remove cap, brush + rod from top, soot falls into firebox + HEPA. Best for most flues.
Bottom-up: brush + rod from firebox upward. Used when roof access dangerous or steep. Requires extra containment + a chimney top stopper rag.
In both: spin the brush, work 18-24" sections, watch for stuck brush (back off + reposition; never force).
Step 5: Smoke chamber + shelf
Above the damper sits the smoke shelf - a horizontal ledge that collects the heaviest debris. Hand-tool + vacuum. This is where 30-40% of glaze + nest material lives.
Step 6: Final inspection
Camera scan again. Confirm:
- Creosote down to Stage 0-1
- No new damage from sweeping
- Damper still functions
- Liner visible + intact
Step 7: Cleanup + customer briefing
- Remove sheeting carefully (roll inward to trap soot)
- HEPA the hearth + 6 ft of floor
- Wipe down mantel + any hearth dust
- Show before/after inspection photos
- Discuss findings + any required repairs
- Recommend next sweep interval
Acceptance criteria
- Creosote reduced to Stage 0 or 1 throughout
- No visible soot in room
- Damper operates
- Camera footage retained for inspection records
- Customer signed work order + has photos
Sweep frequency
Drives next-visit scheduling:
| Use level | Sweep interval |
|---|---|
| Light decorative (4-10 fires/year) | Every 2-3 years |
| Moderate (20-40 fires/year) | Annual |
| Primary heat source | Annual minimum |
| Pellet stove | Annual |
| Gas log (open damper) | Every 2-3 years |
NFPA 211 mandates annual inspection regardless. Sweep is needed when 1/8" creosote present.
Creosote stages
Stage 1: Light, flaky, sooty. Brush removes easily. Standard sweep handles.
Stage 2: Crunchy, tar-like. Heavier brushing + sometimes chemical pretreatment (Anti-Creo-Soot or PCR). Bills higher.
Stage 3: Glazed, glassy, hardened. Brush will not remove. Requires PCR (Poultice Creosote Remover) or rotary chain - expect above standard sweep. Refer if not equipped.
Common pitfalls
- Skipping containment: soot in living room is brand suicide
- Shop-vac instead of HEPA: blows fines into the room
- Force-brushing glaze: cracks tile liner; recommend PCR
- Not photographing: customer disputes findings later
- Forgetting smoke shelf: leaves 30% of debris behind
- Ignoring liner gaps: failed sweep next year + a liability
Safety considerations
- Soot is IARC Group 1 carcinogen - wear P100, change clothes before driving
- Roof work: harness anchored to ridge or proper anchor
- Ladder angle 75 degrees, 3 ft above eave
- Carbon monoxide from prior fires - verify ventilation
- Lifting: brush kits 30-50 lbs, ladders 60 lbs
Photograph the cap before climbing down. A missing or damaged cap is the highest-attach-rate upsell of any sweep visit (35-50% close rate) because the customer can see the gap in their own photo. Animals, rain, downdraft - every cap defect is a same-visit close.
References
- CSIA (Chimney Safety Institute of America) Successful Chimney Sweeping
- NFPA 211 Standard for Chimneys, Fireplaces, Vents, and Solid Fuel-Burning Appliances
- Manuall internal: Annual Chimney Inspection SOP, How to Install a Chimney Cap, Smoke and Draft Problems - Troubleshooting