Exhaust + Ventilation Reference

Why this matters

Exhaust systems remove moisture, odors, smoke, combustion products from homes. Bath fans, range hoods, dryer vents, attic vents, fireplace flues - every service trade touches them. The tech who installs + diagnoses correctly delivers healthy indoor air + prevents structural damage. This is the field card.

Bath exhaust (covered in ventilation fan ratings)

Quick refresher: 1 CFM per sq ft + 50 CFM per fixture; ≤ 1 sone preferred; vent OUT of home (not attic OR soffit).

Kitchen range hood + dryer vent

Range hood sizing: 100 CFM per 12" of cooktop OR 1 CFM per 100 BTU gas. Typical: electric 30" 250 - 300 CFM; gas 30" 300 - 600 CFM (per BTU); pro 48"+ 600 - 1,200+ CFM. Make-up air required > 400 CFM (IRC M1503.4). Mount 24 - 30" above electric; 30 - 36" gas. Duct 6/8/10" round per CFM. Termination roof OR wall (never attic). Sone 5 - 8 typical, quieter premium.

Dryer vent: 4" rigid metal duct preferred (smooth, fire-safe); flex only for transition (max 6 ft per IRC). Termination: louvered cap on exterior wall OR roof; never attic/crawl. Length max 35 ft total equivalent per IRC (subtract 5 ft per 90°; 2.5 ft per 45°). Backflow damper prevents reverse flow. Annual cleaning critical - lint accumulates + causes thousands of fires per year.

Combustion appliance venting

Atmospheric vent (B-vent): gravity-vented furnace / water heater; double-wall metal pipe through roof.

Power vent: blower-driven; PVC OR stainless; horizontal OR vertical.

Direct vent (sealed combustion): outside air for combustion; exhaust + intake separated.

Common locations:

  • B-vent through roof: traditional
  • Side-wall power vent: modern; saves roof penetration
  • Direct vent + intake / exhaust pair: sealed combustion equipment

Required clearances: per manufacturer + NFPA 211 (chimneys); typical:

  • 12" from window OR door
  • 36" from fresh air intake
  • 12" from grade
  • Plus specific cap height above roof

Attic ventilation

Total NFA (net free area): 1 sq ft per 300 sq ft attic (with vapor retarder) OR 1 per 150 (without).

50/50 intake / exhaust split: half soffit, half ridge / gable / roof.

Power attic vent: 600 - 1500 CFM; use only if passive insufficient; can pull conditioned air from house.

Solar attic fan: lower-cost alternative to electric powered.

Avoid: gable vents + ridge vents together (short-circuit air flow).

Crawlspace ventilation

Vented crawl (older code): 1 sq ft NFA per 150 sq ft floor.

Sealed crawl (modern; IRC R408.3): no venting; encapsulated; conditioned. Better moisture control.

Fireplace + chimney venting

Masonry chimney: brick + flue tile; per NFPA 211.

Class A chimney pipe: prefab; insulated double + triple-wall.

Catalytic OR non-catalytic wood stove: specific venting per manufacturer.

Gas fireplace: direct-vent (B-vent OR concentric) OR vent-free (no chimney; CO concern).

Annual sweep: chimney cleaning + inspection.

Roof ventilation

Soffit vents: continuous OR individual; intake air for attic.

Ridge vent: along peak; exhaust attic air.

Gable vent: end-wall louvered; exhaust.

Roof vent (turbine OR static): individual penetrations.

Boot OR roof penetration: vent stack flashing.

Specific duct considerations

Smooth metal duct: lowest friction; preferred for all exhaust.

Flex (insulated): only short runs; many bends OK but each loses CFM.

Termination cap with damper: prevents reverse flow + bug intrusion.

Insulation: cold-climate exhaust ducts (heat loss prevention + condensation reduction).

Common exhaust ventilation problems

Bath fan loud + ineffective: undersized OR crushed duct OR soffit termination.

Dryer slow + hot: lint clogged duct.

Kitchen smoke fills house: range hood undersized OR clogged filter OR not vented outside (recirculating).

Smoke smell coming back: chimney backdraft; depressurized house; cold flue.

CO in living space: blocked OR cracked flue; cracked heat exchanger; depressurized house.

Attic too hot in summer: insufficient ventilation; install ridge + soffit vent.

Moisture in attic + mold growth: bath fan venting into attic; soffit termination; ridge vent inadequate.

Make-up air

Required when: exhaust > 400 CFM (range hood).

Passive: fresh-air intake through wall OR ducting.

Powered: active make-up air system.

Critical: without make-up air, house depressurizes; pulls flue gas back through atmospheric appliances.

Common service-call diagnostics

Test fan: power applied + measure CFM at register.

Test duct: smoke pencil; verify outdoor air movement.

Test backdraft: water heater backdrafting? close house up + run all exhaust; observe.

Test combustion: combustion analyzer (chimney pressure, CO, draft).

Dryer vent cleaning

Tools: rotary brush + vacuum.

Process: from inside OR outside; brush + vacuum lint.

Frequency: annually for typical household; more for high-use.

Common exhaust mistakes

Soffit termination (moisture returns to attic). Attic termination (moisture damage + structural rot). Flex duct used for long runs (friction crushes CFM). Wrong size duct (undersized = slow + restricted). Missing backflow damper. Termination too close to door / window / fresh-air intake (recirculation). Powered attic vent without sealing house (pulls AC air into attic; wastes energy).

Code requirements

IRC M1503: range hoods + kitchen ventilation.

IRC M1505: dryer venting.

IRC M1506: bath ventilation.

ASHRAE 62.2: whole-house ventilation.

Local + state: may exceed national.

Truck stock

Bath fan (Panasonic, Broan; 80 + 110 CFM common), range hood vent connector, dryer vent rotary brush, dryer vent cleaning vacuum, foil tape (181A), flex duct, mastic + brush, anemometer (CFM measurement), smoke pen (leak / draft test), assorted duct fittings (4", 6", 8", 10").

Customer education

Annual maintenance: bath fan + dryer vent cleaning.

Don't run bath fan without supply: pressure issues (rare residential).

Range hood at high while cooking: not just brief use.

Open window when fireplace lit: combustion air for traditional + airflow.

Test smoke + CO detector monthly: covered separately.

The single most-impactful exhaust-vent habit is the BACKDRAFT TEST during furnace + water heater service. Close all windows + doors + run bath fans + dryer + kitchen hood at high. Then check water heater + furnace flue with smoke pen at vent hood - if smoke pulls AWAY from flue, draft is good; if smoke goes INTO living space (backdraft), the house is pulling flue gases back inside. Solutions: better venting, sealed combustion equipment, makeup air. Customer's family is potentially breathing CO without knowing; the 2-minute test reveals the issue. Especially important for atmospheric water heaters + furnaces in basement.

References

  • IRC M1503, M1505, M1506 (vent code requirements)
  • ASHRAE 62.2 (Indoor Air Quality)
  • NFPA 211 (Chimneys, Fireplaces, + Solid Fuel-Burning Appliances)
  • UL 181 (HVAC Duct Closure)
  • Manuall internal: Ventilation Fan Ratings, Duct Sealing Methods